Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed or Handcart Type;
Structure: Vcb;
Poles Number: 3;
Type: Indoor Vacuum Circuit Breaker;
Function: Isolation,Protection,Automatic Reclosing;
Rated Voltage: 40.5kv;
Rated Current: 1250~4000A;
Mechanical Life: 10000;
Altitude: 1000m;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB;
Standard: IEC 61009-1;
Pole: 1P+N;
Tripping curve: B, C, D;
Rated Current (in): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A;
Mode: Electronic;
Residual Current Type: A, Ac;
Residual Current (LΔn): 30mA, 100mA, 300mA;
Icn: 10kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keyword: circuit breaker;
keyword 2: RCBO;
keyword 3: residual current circuit breaker with overcurrent;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 2p;
Type: a/AC;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 240V AC;
Inc: 6ka;
Tripping Curve: B/C/D;
IP Grade: IP20;
Rated Current: 6-50A;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Auto Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 12kv;
Rated Current: 630/1250;
Application: Outdoor;
Arc-Extinguishing: Vacuum;
Rated Short Circuit Breaking Current: 20/25/31.5ka;
Mechanical Life: 10000 Times;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: ELCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC 60898,GB10963/IEC61009,GB16917;
in: 6,10,16,20,25,32A;
Ue: 230V;
Pole: 1p+N;
|