Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Input Current: 0~1500A;
Rated Capacity: 0~5va;
Accuracy Class: 0.5, 1.0;
Winding Bobbin: PBT;
Rated Frequency: 50/60Hz;
Opening-Closing Structure: Snap;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Usage: Electrical Energy Manage, Building Control System;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Frequency Characteristics: 50 to 400 Hz;
Brand: Grewin;
Shape of Core: Epoxy Encapsulated;
Exterior Material: PBT or ABS Resin UL Flame Retardant Rati;
Interior Insulation: Epoxy Encapsulated;
Isolation Voltage: 2500 Vrms for 1 Minute;
Dielectric Resistance: 1000m Ohms @ 500 VDC;
Surge Withstand: 5000V;
Rated Load Resistance: 100K Ohms;
Accuracy Class: as Defined in IEC 60044-1;
Operating Temperature: -25 to +55c, -40 to +85c Optional;
Cetificate: CE-Approved;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Usage: Electrical Energy Manage, Building Control System;
Frequency Characteristics: 50 to 400 Hz;
Shape of Core: Epoxy Encapsulated;
Brand: Grewin;
Frequency: 50-2.5kHz;
Rated Input: 0.5A-630A;
Measuring Range: 10%in-130%in;
Rated Output: 0.333V(AC) or 0-5A;
Dielectric Strength: 5.0kv/1mA/1min;
Case: ABS/UL94-V0;
Bobbin: PBT;
Output Connection: Terminal or UL1015 22AWG Wire 1.5m;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Usage: Electrical Energy Manage, Building Control System;
Frequency Characteristics: 50 to 400 Hz;
Shape of Core: Epoxy Encapsulated;
Brand: Grewin;
Exterior Material: PBT or ABS Resin UL Flame Retardant Rati;
Interior Insulation: Epoxy Encapsulated;
Isolation Voltage: 2500 Vrms for 1 Minute;
Dielectric Resistance: 1000m Ohms @ 500 VDC;
Surge Withstand: 5000V;
Rated Load Resistance: 100K Ohms;
Accuracy Class: as Defined in IEC 60044-1;
Operating Temperature: -25 to +55c, -40 to +85c Optional;
Cetificate: CE-Approved;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Usage: Electrical Energy Manage, Building Control System;
Frequency Characteristics: 50 to 400 Hz;
Shape of Core: Silicon Steel;
Brand: Grewin;
Frequency: 50-400Hz;
Rated Input: 5A-3000A;
Measuring Range: 5%in-130%in;
Rated Output: 0-10V(AC) or 0-5A;
Dielectric Strength: 2.5kv/1mA/1min;
Case: PC /UL94-V0;
Bobbin: PBT;
Internal Structure: Epoxy;
Construction: Tie;
Output Connection: UL1015 22AWG Wire(Twinsted Wire) 2.5m;
|